PRODUCT INFORMATION: Systems for plugging into a groove that keep using locking lug without additional fastening.
The optimum plate thickness of the installation space is as follows: MBS56x12x12 2.50 mm MBS64x10x10 1.00 mm
Article number
H mm
h mm
L mm
l mm
B mm
b mm
t mm
Force* N
Weight g
Temperature °C
MBS56x12x12
12.2
56
52
12
11
2.2
85
24
60
MBS64x10x14
14.3
2
64
54
9.8
0.7
100
35
90
* The forces have been determined at room temperature on a plate in polished steel (S235JR according to DIN 10 025) with a thickness of 10 mm (1kg ~ 10N). A maximum deviation of -10% compared to the specified value is possible in exceptional cases. Value is exceeded in general. Depending on the type of application (installation situation, temperatures, counter anchor etc.) the forces can be influenced enormously. The indicated values are serving as an orientation. Please get advice and help from our experts.