Bar magnets of Samarium-Cobalt (SmCo)
Bar magnet of SmCo, brass body, with fitting tolerance h6
PRODUCT INFORMATION:
Direct mounting of the bar magnet in iron reduced the holding power by up to 15% due to magnetic short circuiting. To avoid this, certain distances need to be maintained between the brass casing of the bar magnet and the iron. The distances are also to be adhered to if the bar magnet was shortened by dimension A. Please refer to the above column for recommended distances (distance mm).
The holding surface is ground and therefore not galvanised.
Alternative to the standard we also offer individual solutions:
» Stainless steel housing
» Housing completely galvanised to better corrosion protection
» Higher temperature until 280 °C
» Stainless steel pole shoes
* The forces have been determined at room temperature on a polished plate made of steel (S235JR according to DIN 10 025) with a thickness of 10 mm (1kg~10N). A deviation of up to -10% from the specified value is possible in exceptional cases. In general, the value is exceeded. The type of application (installation situation, temperatures, counter anchors, etc.) sometimes influence the forces enormously. The values given are for orientation purposes. Let our experts advise you.